View as Grid List
Legrand-Pass & Seymour 2087-BK Spec-Grade Dead Front 20A Self-Test GFCI Receptacle, Black
  • Part of the all-new radiant collection.
  • Rated as a 1 ½ HP motor control switch
  • Conducts an automatic test every three seconds, ensuring it’s always ready to protect. If the device fails the test, the indicator light flashes to signal that the GFCI should be replaced. It also has our proven SafeLock protection feature: if critical components are damaged and protection is lost, power to the receptacle is disconnected
  • Thinner than competitors’ GFCI Receptacles: leaves more room for wires in the box
  • Auto-Ground clip assures a positive ground to metal box
  • Feed-thru wiring configuration allows GFCI to protect downstream receptacles
  • Prevents line-load reversal miswire: no power to the face or downstream receptacles if wired incorrectly
  • Exceeds UL 943 voltage surge requirements; survives 100x the required UL 3kA/6kV voltage surge test cycles
  • Trip indicator light (red LED)
  • Side or internal screw-pressure-plate back wire with #10-#14 AWG solid or stranded copper wire
  • Two back-wire holes per terminal
  • Ground screw has back-wire clamp for easy installation
  • Mounting screws are shipped captive in the device and wall plate for easier installation
  • High-impact-resistant thermoplastic construction.
  • Extra-long strap
  • Button colors match the device face
  • Dual-direction test and reset buttons
  • Supplied with matching TP wall plate
  • Trip Threshold: 5 +/- 1 m
  • Trip Time: 0.025 sec., nominal per UL Standard
Legrand-Pass & Seymour 2087-I Spec-Grade Dead Front 20A Self-Test GFCI Receptacle, Ivory
  • Part of the all-new radiant collection.
  • Rated as a 1 ½ HP motor control switch
  • Conducts an automatic test every three seconds, ensuring it’s always ready to protect. If the device fails the test, the indicator light flashes to signal that the GFCI should be replaced. It also has our proven SafeLock protection feature: if critical components are damaged and protection is lost, power to the receptacle is disconnected
  • Thinner than competitors’ GFCI Receptacles: leaves more room for wires in the box
  • Auto-Ground clip assures a positive ground to metal box
  • Feed-thru wiring configuration allows GFCI to protect downstream receptacles
  • Prevents line-load reversal miswire: no power to the face or downstream receptacles if wired incorrectly
  • Exceeds UL 943 voltage surge requirements; survives 100x the required UL 3kA/6kV voltage surge test cycles
  • Trip indicator light (red LED)
  • Side or internal screw-pressure-plate back wire with #10-#14 AWG solid or stranded copper wire
  • Two back-wire holes per terminal
  • Ground screw has back-wire clamp for easy installation
  • Mounting screws are shipped captive in the device and wall plate for easier installation
  • High-impact-resistant thermoplastic construction.
  • Extra-long strap
  • Button colors match the device face
  • Dual-direction test and reset buttons
  • Supplied with matching TP wall plate
  • Trip Threshold: 5 +/- 1 m
  • Trip Time: 0.025 sec., nominal per UL Standard
Legrand-Pass & Seymour 2087-LA Spec-Grade Dead Front 20A Self-Test GFCI Receptacle, Light Almond
  • Part of the all-new radiant collection.
  • Rated as a 1 ½ HP motor control switch
  • Conducts an automatic test every three seconds, ensuring it’s always ready to protect. If the device fails the test, the indicator light flashes to signal that the GFCI should be replaced. It also has our proven SafeLock protection feature: if critical components are damaged and protection is lost, power to the receptacle is disconnected
  • Thinner than competitors’ GFCI Receptacles: leaves more room for wires in the box
  • Auto-Ground clip assures a positive ground to metal box
  • Feed-thru wiring configuration allows GFCI to protect downstream receptacles
  • Prevents line-load reversal miswire: no power to the face or downstream receptacles if wired incorrectly
  • Exceeds UL 943 voltage surge requirements; survives 100x the required UL 3kA/6kV voltage surge test cycles
  • Trip indicator light (red LED)
  • Side or internal screw-pressure-plate back wire with #10-#14 AWG solid or stranded copper wire
  • Two back-wire holes per terminal
  • Ground screw has back-wire clamp for easy installation
  • Mounting screws are shipped captive in the device and wall plate for easier installation
  • High-impact-resistant thermoplastic construction.
  • Extra-long strap
  • Button colors match the device face
  • Dual-direction test and reset buttons
  • Supplied with matching TP wall plate
  • Trip Threshold: 5 +/- 1 m
  • Trip Time: 0.025 sec., nominal per UL Standard
Legrand-Pass & Seymour 2087-W Spec-Grade Dead Front 20A Self-Test GFCI Receptacle, White
  • Part of the all-new radiant collection.
  • Rated as a 1 ½ HP motor control switch
  • Conducts an automatic test every three seconds, ensuring it’s always ready to protect. If the device fails the test, the indicator light flashes to signal that the GFCI should be replaced. It also has our proven SafeLock protection feature: if critical components are damaged and protection is lost, power to the receptacle is disconnected
  • Thinner than competitors’ GFCI Receptacles: leaves more room for wires in the box
  • Auto-Ground clip assures a positive ground to metal box
  • Feed-thru wiring configuration allows GFCI to protect downstream receptacles
  • Prevents line-load reversal miswire: no power to the face or downstream receptacles if wired incorrectly
  • Exceeds UL 943 voltage surge requirements; survives 100x the required UL 3kA/6kV voltage surge test cycles
  • Trip indicator light (red LED)
  • Side or internal screw-pressure-plate back wire with #10-#14 AWG solid or stranded copper wire
  • Two back-wire holes per terminal
  • Ground screw has back-wire clamp for easy installation
  • Mounting screws are shipped captive in the device and wall plate for easier installation
  • High-impact-resistant thermoplastic construction.
  • Extra-long strap
  • Button colors match the device face
  • Dual-direction test and reset buttons
  • Supplied with matching TP wall plate
  • Trip Threshold: 5 +/- 1 m
  • Trip Time: 0.025 sec., nominal per UL Standard